Covered Patio Design Standards PCBC 02/03
Note: If these designs are used to obtain a permit the design may not be field changed.
1. All Wood To Be Douglas Fir No. 2 Or Better.
2. Concrete Grade - Minimum 2,500 PSI.
3. Re-Bar - Grade 40 (Minimum).
4. Roof Nailing 8d Nails At 6” 0.Cedges And 12” '0.C. Field.
5. Minimum Concrete Toe - Dn. At 6” X 6” Of 1 - #3 Re-Bar.
6. Assumed Soil Bearing 1,500 P.S.F.
7. Porch Framing Based On 30# Dead Load And Live Load.
8. Metal Connecters To Be I.C.B.O. Approved.
Framing Chart |
||||
Depth |
Beam |
Rafter |
Post |
Footing |
10'-0" |
4x8 |
2x6 @ 24" O.C. |
4x4 |
18" Sq. x 12" D |
12"-0" |
4x8 |
2x8 @ 24" O.C. |
4x6 |
24" Sq. x 12" D |